<source id="1odgi"><input id="1odgi"></input></source>
<video id="1odgi"></video>
<wbr id="1odgi"><ins id="1odgi"><progress id="1odgi"></progress></ins></wbr>
<listing id="1odgi"></listing>
<listing id="1odgi"></listing>
<listing id="1odgi"></listing>
<listing id="1odgi"><source id="1odgi"><input id="1odgi"></input></source></listing>
 
 
 
 
DN15-50mm, threads end
Multi-jet
Single-jet
Rotary Piston
Bypass
DN50-500, Flanged end
Accessories
 
Single-jet
 
CD06TAR-15E (cold water(hot water))
 

APPLICATION: MEASURING THE TOTAL VOLUME OF COLD POTABLE WATER PASSING THROUGH THE METER,IT'S SUITABLE FOR DOMESTIC USE.
 
OPERATING CONDITION:
THE MAX.ADMISSIBLE WATER PRESSURE: 1.6MPa.
WATER TEMP.: UP TO 50℃
 
SPECIALITY:
*Magnetic shield structure, with which the water meter can
  not be influenced by outside magnetic fields.
* If be replaced with the appropriate materials, it can be used for the
   hot water meter (the water temperature is above 90℃).
Maximum permissible error:
Between qt (included) and qs is ±2%;
Between qmin and qt (excluded) is ±5%.
NOTE: The technical data conform to ISO4064 standard, class B.

FLOW-ERROR CURVE

SPECIFICATION AND OVERALL DIMENSIONS
Description
Unit

Hydraulic data and dimensions

Nominal size
mm

15

inch

1/2

Overload flow-rate (qs)
m3/h

3

Permanent flow-rate (qp)
m3/h

1.5

Transitional flow-rate (qt)
l/h

120

Minimum flow-rate (qmin)
l/h

30

Min. reading
l

0.05

Max. reading
m3

99999.9999

Nominal pressure
MPa

1.6

ΔP at the qs
MPa

≤0.10

L
mm

110

I
mm

190

mm

68

H
mm

76


                       OVERALL DIMENSIONS                                                                         PRESSURE LOSS CURVE

 

  All rights reserved: Lianyungang Lianli Water Meter Co.,Ltd. Tel: 0086-518-82341113 Fax: 0086-518-82340789
Add: Lianyungang economic and technological development zone, jiangsu, china
P.C: 222047 E-mail : lianli@lianliwm.com Support: Sooba.cn 
色妞AV永久一区二区国产AV_日本久久久久亚洲中字幕_台湾佬中文娱乐中文娱乐22丨_亚洲国产无码综合一区二区